ResQ-Window

The BS 8524-1 compliant ResQ-Window™ is a vision panel window for fire curtains which can be installed into a Coopers Fire fire curtain allowing building occupants and first responders to see through the curtain after it has been deployed.
Coopers Fire ResQ Window Vision Panel for Fire Curtains
Coopers Fire ResQ Window Vision Panel for Fire Curtains
Coopers Fire ResQ Window Vision Panel for Fire Curtains
Coopers Fire ResQ Window Vision Panel for Fire Curtains

KEY INFORMATION

Curtain type:
Fire

Product Standards:
BS, EN

Standard:
BS EN 1634-3, BS 8524-1, BS EN 1634-1, BS EN 13501-2

Orientation:
Vertical

Rating:
30 MINUTES, 60 MINUTES, 90 MINUTES, 120 MINUTES

Special features:
Compliant to BS 8524-1, Fully tested to BS EN 1634-1 , Can withstand temperatures in excess of 1000 degrees celsius , 2 hours integrity (120 minutes fire resistance), Product certified through Warrington's CERTIFIRE scheme

DOWNLOADS

ResQ-Window Vision Panel

FIRE RESISTANCE OR CLASSIFICATION: E120 EW30 (E = Integrity for 120mins, EW = Radiance for 30mins)

 

ResQ-Window™ is a patented translucent fire proof flexible material that can be installed into a Coopers Fire fire curtain allowing building occupants and first responders to see through the curtain after it has been deployed.

 

ResQ-Window™ can withstand temperatures in excess of 1000oC with 2 hours integrity (E120) and compliant to BS 8524-1. The curtain with a vision panel is designed for:

  • Escape routes incorporating doorways and corridors
  • Lift openings and lobbies
  • Areas where Fire Marshals and the Fire and Rescue Service may need to assess prior to entry

BS 9999 and Approved Document B both reference the requirement and benefits of vision panels used in fire safety in occupied buildings.

 

The ResQ-Window™ can be positioned to allow a low and high level view through the curtain if required.

 

BENEFITS

  • See through a deployed curtain as a means of escape
  • Safely egress from lifts
  • Suitable for lift lobby muster points
  • First responder can clear a building faster
  • First responder can see the presence of an occupant on the other side of a curtain
  • First responder can see the presence of fire on the other side of a curtain
  • First responder can see the presence of smoke on the other side of a curtain
  • BS 8524-1 compliant

 

GET IN TOUCH

T: +44 (0)2392 454 405

F: +44 (0)2392 492 732

info@coopersfire.com

PRODUCT SELECTOR - FILTER THE CATEGORIES BELOW, TO FIND YOUR PRODUCT